CALIBRATION OF A PARSHALL FLUME
DOI:
https://doi.org/10.56238/ramv20n16-015Keywords:
Parshall Flume, Calibration, Open Channel, Inverted Siphon, Flow RateAbstract
This study aims to verify the equation governing the flow rate through a 2-inch-throat Parshall flume, since standard flumes are typically based on a 3-inch throat. The purpose is to verify the agreement of the observed flow with the mathematical formula derived from the data provided by the manufacturer, using a 2/3-scale flume upstream of the throat with a resolution of In addition to calibrating this flume, the goal is to improve the resolution of this scale to .
References
ALENCAR, Ronildo Inácio Soares; MELO, Weslley Imperiano Gomes de; Análise das incertezas na determinação do volume de um cilindro metálico pelo método gravimétrico e por medição do diâmetro e altura; João Pessoa; 23/08/2010.
Fenômenos da Engenharia. Disponível em: https://fenomenosdaengenharia.blogspot.com/2013 /06/calha-parshall.html. Acessada em 25/05/2026.
FOX, Robert W.; MCDONALD, Alan T.; PRITCHARD, Philip J. Mecânica dos Fluidos; 6ª edição. Rio de Janeiro: LTC, 2006.
SPIEGEL, Murray R. Estatística. Tradução de Pedro Cosentino. São Paulo: McGraw-Hill do Brasil, 1976.